Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Sci Total Environ ; 877: 162779, 2023 Jun 15.
Article in English | MEDLINE | ID: covidwho-2258722

ABSTRACT

With the outbreak and spread of the COVID-19 epidemic, HCWs are frequently required to wear personal protective equipment (PPE) for nucleic acid sample collection in semi-open transition spaces. Wearing PPE causes significant psychological and physical stress in HCWs. In this study, operative temperature (Top) and wet-bulb globe temperature (WBGT) were used to assess thermal conditions through field experiments, while multiple physiological parameters were measured in the subjects. The results indicated that the subjects showed statistically significant differences in thermal perception and physiological parameters with and without PPE. Using observed increases in heart rate (HR), auditory canal temperature (Tac), mean skin temperature (MST), and end-tidal CO2 pressure, subjects were shown to have an increased metabolic rate and heat storage while wearing PPE. Additionally, a decrease in oxygen concentration was also observed, and this decrease may be linked to fatigue and cognitive impairment. Moreover, HR, MST, and Tac showed a significant linear relationship, which increased with temperature and operative temperature, and the HR response was stronger with PPE than without PPE. The neutral, preferred, and acceptable temperatures were significantly lower with PPE than without PPE, and the deviations for neutral Top/WBGT were 9.5/7.1 °C and preferred Top/WBGT was 2.2/4.0 °C, respectively. Moreover, the upper limits of acceptable WBGT, 29.4 °C with PPE and 20.4 °C without PPE, differed significantly between the two phases. Furthermore, the recorded physiological parameter responses and thermal perception responses of the subjects while wearing PPE indicated that they were at risk of thermal stress. Overall, these results suggest that people who wear PPE should focus on their health and thermal stress. This study provides a reference for the development of strategies to counteract heat stress and improve thermal comfort.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , Personal Protective Equipment , Skin Temperature , Stress, Physiological , Heat-Shock Response , Hot Temperature
2.
Biosensors (Basel) ; 12(12)2022 Nov 29.
Article in English | MEDLINE | ID: covidwho-2258634

ABSTRACT

Wearable sensors and machine learning algorithms are widely used for predicting an individual's thermal sensation. However, most of the studies are limited to controlled laboratory experiments with inconvenient wearable sensors without considering the dynamic behavior of ambient conditions. In this study, we focused on predicting individual dynamic thermal sensation based on physiological and psychological data. We designed a smart face mask that can measure skin temperature (SKT) and exhaled breath temperature (EBT) and is powered by a rechargeable battery. Real-time human experiments were performed in a subway cabin with twenty male students under natural conditions. The data were collected using a smartphone application, and we created features using the wavelet decomposition technique. The bagged tree algorithm was selected to train the individual model, which showed an overall accuracy and f-1 score of 98.14% and 96.33%, respectively. An individual's thermal sensation was significantly correlated with SKT, EBT, and associated features.


Subject(s)
Masks , Railroads , Humans , Skin Temperature , Temperature , Thermosensing/physiology
3.
Int J Environ Res Public Health ; 20(1)2022 12 29.
Article in English | MEDLINE | ID: covidwho-2246783

ABSTRACT

While personal protective equipment (PPE) protects healthcare workers from viruses, it also increases the risk of heat stress. In this study, the effects of environmental heat stress, the insulation of the PPE inner-garment layer, and the personal cooling strategy on the physiological and perceptual responses of PPE-clad young college students were evaluated. Three levels of wet bulb globe temperatures (WBGT = 15 °C, 28 °C, and 32 °C) and two types of inner garments (0.37 clo and 0.75 clo) were chosen for this study. In an uncompensable heat stress environment (WBGT = 32 °C), the effects of two commercially available personal cooling systems, including a ventilation cooling system (VCS) and an ice pack cooling system (ICS) on the heat strain mitigation of PPE-clad participants were also assessed. At WBGT = 15 °C with 0.75 clo inner garments, mean skin temperatures were stabilized at 31.2 °C, Hskin was 60-65%, and HR was about 75.5 bpm, indicating that the working scenario was on the cooler side. At WBGT = 28 °C, Tskin plateaued at approximately 34.7 °C, and the participants reported "hot" thermal sensations. The insulation reduction in inner garments from 0.75 clo to 0.37 clo did not significantly improve the physiological thermal comfort of the participants. At WBGT = 32 °C, Tskin was maintained at 35.2-35.7 °C, Hskin was nearly 90% RH, Tcore exceeded 37.1 °C, and the mean HR was 91.9 bpm. These conditions indicated that such a working scenario was uncompensable, and personal cooling to mitigate heat stress was required. Relative to that in NCS (no cooling), the mean skin temperatures in ICS and VCS were reduced by 0.61 °C and 0.22 °C, respectively, and the heart rates were decreased by 10.7 and 8.5 bpm, respectively. Perceptual responses in ICS and VCS improved significantly throughout the entire field trials, with VCS outperforming ICS in the individual cooling effect.


Subject(s)
Body Temperature Regulation , Heat Stress Disorders , Humans , Protective Clothing , Cold Temperature , Temperature , Skin Temperature , Heat Stress Disorders/prevention & control , Hot Temperature
4.
Adv Skin Wound Care ; 35(10): 555-565, 2022 Oct 01.
Article in English | MEDLINE | ID: covidwho-2070167

ABSTRACT

OBJECTIVE: To determine whether changes in skin temperature can affect the integrity of skin. METHODOLOGY: The authors conducted a systematic literature search as per the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) guidelines. They searched the CINAHL (Cumulative Index to Nursing and Allied Health Literature), Cochrane, MEDLINE Complete, Academic Search Ultimate, and HyDi databases for articles examining the effects of skin temperature on skin integrity published through April 2020. Two independent reviewers scored the methodologic quality of the 13 included studies. RESULTS: Only 11 studies were included in the qualitative analysis, as the other two articles had a critical risk of bias. There is strong evidence to indicate that an increase in skin temperature leads to changes in skin structure and function. However, ulcer formation was more affected by intrinsic and extrinsic factors, rather than by temperature alone. CONCLUSION: Further high-quality randomized controlled trials are required to investigate the direct effect of skin temperature on ulceration.


Subject(s)
Skin Temperature , Skin Ulcer , Skin , Humans , Skin/pathology , Skin Ulcer/pathology
5.
PLoS One ; 17(7): e0268065, 2022.
Article in English | MEDLINE | ID: covidwho-1923678

ABSTRACT

RATIONALE: Vital signs follow circadian patterns in both healthy volunteers and critically ill patients, which seem to be influenced by disease severity in the latter. In this study we explored the existence of circadian patterns in heart rate, respiratory rate and skin temperature of hospitalized COVID-19 patients, and aimed to explore differences in circadian rhythm amplitude during patient deterioration. METHODS: We performed a retrospective study of COVID-19 patients admitted to the general ward of a tertiary hospital between April 2020 and March 2021. Patients were continuously monitored using a wireless sensor and fingertip pulse oximeter. Data was divided into three cohorts: patients who recovered, patients who developed respiratory insufficiency and patients who died. For each cohort, a population mean cosinor model was fitted to detect rhythmicity. To assess changes in amplitude, a mixed-effect cosinor model was fitted. RESULTS: A total of 429 patients were monitored. Rhythmicity was observed in heartrate for the recovery cohort (p<0.001), respiratory insufficiency cohort (p<0.001 and mortality cohort (p = 0.002). Respiratory rate showed rhythmicity in the recovery cohort (p<0.001), but not in the other cohorts (p = 0.18 and p = 0.51). Skin temperature also showed rhythmicity in the recovery cohort (p<0.001), but not in the other cohorts (p = 0.22 and p = 0.12). For respiratory insufficiency, only the amplitude of heart rate circadian pattern increased slightly the day before (1.2 (99%CI 0.16-2.2, p = 0.002)). In the mortality cohort, the amplitude of heart rate decreased (-1.5 (99%CI -2.6- -0.42, p<0.001)) and respiratory rate amplitude increased (0.72 (99%CI 0.27-1.3, p = 0.002) the days before death. CONCLUSION: A circadian rhythm is present in heart rate of COVID-19 patients admitted to the general ward. For respiratory rate and skin temperature, rhythmicity was only found in patients who recover, but not in patients developing respiratory insufficiency or death. We found no consistent changes in circadian rhythm amplitude accompanying patient deterioration.


Subject(s)
COVID-19 , Respiratory Insufficiency , Circadian Rhythm/physiology , Heart Rate/physiology , Humans , Respiratory Rate , Retrospective Studies , Skin Temperature
6.
Sensors (Basel) ; 22(3)2022 Jan 22.
Article in English | MEDLINE | ID: covidwho-1686937

ABSTRACT

There is a need to rapidly screen individuals for heat strain and fever using skin temperature (Tsk) as an index of deep body temperature (Tb). This study's aim was to assess whether Tsk could serve as an accurate and valid index of Tb during a simulated heatwave. Seven participants maintained a continuous schedule over 9-days, in 3-day parts; pre-/post-HW (25.4 °C), simulated-HW (35.4 °C). Contact thermistors measured Tsk (Tforehead, Tfinger); radio pills measured gastrointestinal temperature (Tgi). Proximal-distal temperature gradients (ΔTforehead-finger) were also measured. Measurements were grouped into ambient conditions: 22, 25, and 35 °C. Tgi and Tforehead only displayed a significant relationship in 22 °C (r: 0.591; p < 0.001) and 25 °C (r: 0.408; p < 0.001) conditions. A linear regression of all conditions identified Tforehead and ΔTforehead-finger as significant predictors of Tgi (r2: 0.588; F: 125.771; p < 0.001), producing a root mean square error of 0.26 °C. Additional residual analysis identified Tforehead to be responsible for a plateau in Tgi prediction above 37 °C. Contact Tforehead was shown to be a statistically suitable indicator of Tgi in non-HW conditions; however, an error of ~1 °C makes this physiologically redundant. The measurement of multiple sites may improve Tb prediction, though it is still physiologically unsuitable, especially at higher ambient temperatures.


Subject(s)
Body Temperature , Skin Temperature , Fever , Forehead , Hot Temperature , Humans , Temperature
7.
Int J Environ Res Public Health ; 18(24)2021 12 12.
Article in English | MEDLINE | ID: covidwho-1593103

ABSTRACT

Exoskeletons and exosuits (exos) are wearable devices that physically assist movement. User comfort is critically important for societal adoption of exos. Thermal comfort (a person's satisfaction with their thermal environment) represents a key design challenge. Exos must physically attach/interface to the body to apply forces, and these interfaces inevitably trap some heat. It is envisioned that thermal comfort could be improved by designing mode-switching exo interfaces that temporarily loosen around a body segment when assistive forces are not being applied. To inform exo design, a case series study (N = 4) based on single-subject design principles was performed. Our objective was to assess individual responses to skin temperature and thermal comfort during physical activity with a Loose leg-sleeve interface compared with a Form-Fitting one, and immediately after a Form-Fitting sleeve switched to Loose. Skin under the Loose sleeve was 2-3 °C (4-6 °F) cooler after 25 min of physical activity, and two of four participants reported the Loose sleeve improved their thermal comfort. After completion of the physical activity, the Form-Fitting sleeve was loosened, causing a 2-4 °C (3-8 °F) drop in skin temperature underneath for all participants, and two participants to report slightly improved thermal comfort. These findings confirmed that an exo that can quickly loosen its interface when assistance is not required-and re-tighten when it is- has the potential to enhance thermal comfort for some individuals and environments. More broadly, this study demonstrates that mode-switching mechanisms in exos can do more than adjust physical assistance: they can also exploit thermodynamics and facilitate thermoregulation in a way that enhances comfort for exo users.


Subject(s)
Exoskeleton Device , Body Temperature Regulation , Exercise , Hot Temperature , Humans , Skin Temperature
8.
Appl Physiol Nutr Metab ; 46(7): 753-762, 2021 Jul.
Article in English | MEDLINE | ID: covidwho-1571437

ABSTRACT

We sought to determine the impact of wearing cloth or surgical masks on the cardiopulmonary responses to moderate-intensity exercise. Twelve subjects (n = 5 females) completed three, 8-min cycling trials while breathing through a non-rebreathing valve (laboratory control), cloth, or surgical mask. Heart rate (HR), oxyhemoglobin saturation (SpO2), breathing frequency, mouth pressure, partial pressure of end-tidal carbon dioxide (PetCO2) and oxygen (PetO2), dyspnea were measured throughout exercise. A subset of n = 6 subjects completed an additional exercise bout without a mask (ecological control). There were no differences in breathing frequency, HR or SpO2 across conditions (all p > 0.05). Compared with the laboratory control (4.7 ± 0.9 cmH2O [mean ± SD]), mouth pressure swings were smaller with the surgical mask (0.9 ± 0.7; p < 0.0001), but similar with the cloth mask (3.6 ± 4.8 cmH2O; p = 0.66). Wearing a cloth mask decreased PetO2 (-3.5 ± 3.7 mm Hg) and increased PetCO2 (+2.0 ± 1.3 mm Hg) relative to the ecological control (both p < 0.05). There were no differences in end-tidal gases between mask conditions and laboratory control (both p > 0.05). Dyspnea was similar between the control conditions and the surgical mask (p > 0.05) but was greater with the cloth mask compared with laboratory (+0.9 ± 1.2) and ecological (+1.5 ± 1.3) control conditions (both p < 0.05). Wearing a mask during short-term moderate-intensity exercise may increase dyspnea but has minimal impact on the cardiopulmonary response. Novelty: Wearing surgical or cloth masks during exercise has no impact on breathing frequency, tidal volume, oxygenation, and heart rate However, there are some changes in inspired and expired gas fractions that are physiologically irrelevant. In young healthy individuals, wearing surgical or cloth masks during submaximal exercise has few physiological consequences.


Subject(s)
Exercise/physiology , Heart Rate , Masks , Oxyhemoglobins/metabolism , Respiratory Rate , Adult , COVID-19/prevention & control , Carbon Dioxide/physiology , Dyspnea/physiopathology , Equipment Design , Exercise Test , Face , Female , Humans , Male , Mouth/physiology , Oxygen/physiology , Partial Pressure , Pressure , Skin Temperature , Tidal Volume , Young Adult
9.
Adv Mater ; 34(4): e2105865, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1530085

ABSTRACT

Monitoring the body temperature with high accuracy provides a fast, facile, yet powerful route about the human body in a wide range of health information standards. Here, the first ever ultrasensitive and stretchable gold-doped silicon nanomembrane (Au-doped SiNM) epidermal temperature sensor array is introduced. The ultrasensitivity is achieved by shifting freeze-out region to intrinsic region in carrier density and modulation of fermi energy level of p-type SiNM through the development of a novel gold-doping strategy. The Au-doped SiNM is readily transferred onto an ultrathin polymer layer with a well-designed serpentine mesh structure, capable of being utilized as an epidermal temperature sensor array. Measurements in vivo and in vitro show temperature coefficient of resistance as high as -37270.72 ppm °C-1 , 22 times higher than existing metal-based temperature sensors with similar structures, and one of the highest thermal sensitivity among the inorganic material based temperature sensors. Applications in the continuous monitoring of body temperature and respiration rate during exercising are demonstrated with a successful capture of information. This work lays a foundation for monitoring body temperature, potentially useful for precision diagnosis (e.g., continuous monitoring body temperature in coronavirus disease 2019 cases) and management of disease relevance to body temperature in healthcare.


Subject(s)
Gold/chemistry , Nanostructures/chemistry , Silicon/chemistry , Biosensing Techniques , Finite Element Analysis , Humans , Molecular Dynamics Simulation , Polymers/chemistry , Skin , Skin Temperature , Wearable Electronic Devices , Wireless Technology
10.
Ind Health ; 59(5): 325-333, 2021 Oct 05.
Article in English | MEDLINE | ID: covidwho-1363586

ABSTRACT

Surgical masks are widely used for the prevention of respiratory infections. However, the risk of heat stroke during intense work or exercise in hot and humid environment is a concern. This study aimed to examine whether wearing a surgical mask increases the risk of heat stroke during mild exercise in such environment. Twelve participants conducted treadmill exercise for 30 min at 6 km/h, with 5% slope, 35°C ambient temperature, and 65% relative humidity, while wearing or not a surgical mask (mask and control trials, respectively). Rectal temperature (Trec), ear canal temperature (Tear), and mean skin temperature (mean Tskin) were assessed. Skin temperature and humidity of the perioral area of the face (Tface and RHface) were also estimated. Thermal sensation and discomfort, sensation of humidity, fatigue, and thirst were rated using the visual analogue scale. Trec, Tear, mean Tskin, and Tface increased during the exercise, without any difference between the two trials. RHface during the exercise was greater in the mask trial. Hot sensation was greater in the mask trial, but no influence on fatigue and thirst was found. These results suggest that wearing a surgical mask does not increase the risk of heat stroke during mild exercise in moist heat.


Subject(s)
Heat Stroke , Masks , Body Temperature , Body Temperature Regulation , Heart Rate , Hot Temperature , Humans , Humidity , Skin Temperature
11.
Sci Rep ; 11(1): 11901, 2021 06 07.
Article in English | MEDLINE | ID: covidwho-1260949

ABSTRACT

The COVID-19 pandemic has led to the rapid adoption and rollout of thermal camera-based Infrared Thermography (IRT) systems for fever detection. These systems use facial infrared emissions to detect individuals exhibiting an elevated core-body temperature, which is present in many symptomatic presentations of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Despite the rollout of these systems, there is little independent research supporting their efficacy. The primary objective of this study was to assess the precision and accuracy of IRT screening solutions in a real-world scenario. The method used was a single-centre, observational study investigating the agreement of three IRT systems compared to digital oral thermometer measurements of body temperature. Over 5 days, 107 measurements were taken from individuals wearing facial masks. During each entry, two measurements of the subject's body temperature were made from each system to allow for the evaluation of the measurement precision, followed by an oral thermometer measurement. Each participant also answered a short demographic survey. This study found that the precision of the IRT systems was wider than 0.3 °C claimed accuracy of two of the systems. This study also found that the IRT measurements were only weakly correlated to those of the oral temperature. Additionally, it was found that demographic characteristics (age, gender, and mask-type) impacted the measurement error. This study indicates that using IRT systems in front-line scenarios poses a potential risk, where a lack of measurement accuracy could possibly allow febrile individuals to pass through undetected. Further research is required into methods which could increase accuracy and improve the techniques viability.


Subject(s)
Body Temperature/physiology , COVID-19/prevention & control , SARS-CoV-2/pathogenicity , Skin Temperature/physiology , COVID-19/diagnosis , Humans , Infrared Rays , Mass Screening/methods , Thermometers
12.
Sensors (Basel) ; 21(5)2021 Mar 06.
Article in English | MEDLINE | ID: covidwho-1129769

ABSTRACT

There is a need for continuous, non-invasive monitoring of biological data to assess health and wellbeing. Currently, many types of smart patches have been developed to continuously monitor body temperature, but few trials have been completed to evaluate psychometrics and feasibility for human subjects in real-life scenarios. The aim of this feasibility study was to evaluate the reliability, validity and usability of a smart patch measuring body temperature in healthy adults. The smart patch consisted of a fully integrated wearable wireless sensor with a multichannel temperature sensor, signal processing integrated circuit, wireless communication feature and a flexible battery. Thirty-five healthy adults were recruited for this test, carried out by wearing the patches on their upper chests for 24 h and checking their body temperature six times a day using infrared forehead thermometers as a gold standard for testing validity. Descriptive statistics, one-sampled and independent t-tests, Pearson's correlation coefficients and Bland-Altman plot were examined for body temperatures between two measures. In addition, multiple linear regression, receiver operating characteristic (ROC) and qualitative content analysis were conducted. Among the 35 participants, 29 of them wore the patch for over 19 h (dropout rate: 17.14%). Mean body temperature measured by infrared forehead thermometers and smart patch ranged between 32.53 and 38.2 °C per person and were moderately correlated (r = 0.23-0.43) overall. Based on a Bland-Altman plot, approximately 94% of the measurements were located within one standard deviation (upper limit = 4.52, lower limit = -5.82). Most outliers were identified on the first measurement and were located below the lower limit. It is appropriate to use 37.5 °C in infrared forehead temperature as a cutoff to define febrile conditions. Users' position while checking and ambient temperature and humidity are not affected to the smart patch body temperature. Overall, the participants showed high usability and satisfaction on the survey. Few participants reported discomfort due to limited daily activity, itchy skin or detaching concerns. In conclusion, epidermal electronic sensor technologies provide a promising method for continuously monitoring individuals' body temperatures, even in real-life situations. Our study findings show the potential for smart patches to monitoring non-febrile condition in the community.


Subject(s)
Skin Temperature , Thermometers , Adult , Body Temperature , Feasibility Studies , Humans , Psychometrics , Reproducibility of Results
14.
Dermatitis ; 32(1): 57-62, 2021.
Article in English | MEDLINE | ID: covidwho-1066443

ABSTRACT

BACKGROUND: Coronavirus disease 2019 has rapidly spread all over the world. Personal protective equipment (PPE) including masks and gloves is needed to avoid transmission. Adverse skin reactions associated with PPE have been described, but there is no information regarding objective measures to assess skin impairment related to PPE. OBJECTIVE: The aim of the study was to evaluate the impact of using facial mask and nitrile gloves on epidermal barrier function and skin homeostasis. METHODS: A cross-sectional study was designed. Thirty-four health care workers wearing nitrile gloves and a mask for 2 hours were included. Transepidermal water loss, stratum corneum hydration, erythema, and temperature were measured. RESULTS: Transepidermal water loss (31.11 vs 14.24 g·m-2·h-1), temperature (33.29°C vs 32.57°C), and erythema were significantly greater at the area covered by gloves compared with the noncovered area. Transepidermal water loss (22.82 vs 13.69 g·m-2·h-1), temperature, and erythema (411.43 vs 335.52 arbitrary units) were significantly increased at the area covered by mask, whereas stratum corneum hydration was lower. Transepidermal water loss was greater at the area covered by a surgical mask than at a filtering respirator mask coded filtering facepiece 2 (27.09 vs 18.02 g·m-2·h-1, P = 0.034). CONCLUSIONS: Skin homeostasis and epidermal barrier function may be impaired by gloves and mask use. High-quality PPE should be provided, and adequate skin prevention measures should be implemented to reduce epidermal barrier damage.


Subject(s)
COVID-19/prevention & control , Epidermis/physiopathology , Erythema/etiology , Gloves, Surgical/adverse effects , Health Personnel , N95 Respirators/adverse effects , Skin Temperature/physiology , Water Loss, Insensible/physiology , Adult , Female , Humans , Male , Masks/adverse effects , Middle Aged , Nitriles , Occupational Exposure , Personal Protective Equipment/adverse effects , SARS-CoV-2 , Skin/physiopathology
15.
Ann Palliat Med ; 10(1): 3-9, 2021 Jan.
Article in English | MEDLINE | ID: covidwho-1063562

ABSTRACT

BACKGROUND: COVID-19 is rapidly transmitted and has aroused enormous concern globally. This study aimed to investigate the effect of hydrocolloid dressing combined with 3M Cavilon No-Sting Barrier Film on the prevention of facial pressure injury in medical staff tasked with preventing and controlling COVID-19. METHODS: This was a self-controlled study. Medical staff who treated patients with COVID-19 infection in isolation wards from 6 January to 2 February, 2020, were selected to participate. Phase I was defined as the first 2 weeks of medical personnel entering the isolation ward, with phase II being the following 2 weeks. In phase I, medical workers only used hydrocolloid dressing on their faces, and in phase II, they used both hydrocolloid dressing and 3M Cavilon No-Sting Barrier Film. RESULTS: A total of 116 medical workers were selected as research subjects. The average facial local temperature in phase I was higher than that in phase II from the baseline (day 1) to the end of the study (day 14); however, there was no statistically significant difference (P>0.05). The incidence of facial pressure injury in phase II was lower than that in phase I (P<0.05); the facial skin comfort level among medical staff in phase II was higher than that in phase I (P<0.05). CONCLUSIONS: Hydrocolloid dressing combined with 3M Cavilon No-Sting Barrier Film for facial skin care can effectively reduce the incidence of facial pressure injury and can improve skin comfort level while ensuring isolation and a protective effect.


Subject(s)
Bandages, Hydrocolloid , Eye Protective Devices/adverse effects , Facial Injuries/prevention & control , Masks/adverse effects , Medical Staff, Hospital , Pressure Ulcer/prevention & control , Adult , COVID-19/epidemiology , China/epidemiology , Facial Injuries/etiology , Female , Humans , Male , Pandemics , Pressure Ulcer/etiology , Skin Temperature
16.
PLoS One ; 15(11): e0241843, 2020.
Article in English | MEDLINE | ID: covidwho-945347

ABSTRACT

BACKGROUND: The measurement of body temperature has become commonplace in the current COVID-19 pandemic. Body temperature can be measured using thermal infrared imaging, a safe, non-contact method that relies on the emissivity of the skin being known to provide accurate readings. Skin pigmentation affects the absorption of visible light and enables us to see variations in skin colour. Pigmentation may also affect the absorption of infrared radiation and thus affect thermal imaging. Human skin has an accepted emissivity of 0.98 but the effect of different skin pigmentation on this value is not known. In this study, we investigated the influence of different skin pigmentation on thermal emissivity in 65 adult volunteers. METHODS: A reference object of known emissivity (electrical tape) was applied to participant's skin on the inner upper arm. Tape and arm were imaged simultaneously using a thermal infrared camera. The emissivity was set on the camera to the known value for electrical tape. The emissivity was altered manually until the skin temperature using thermal imaging software was equal to the initial tape temperature. This provided the calculated emissivity value of the skin. Participants were grouped according to skin pigmentation, quantified using the Fitzpatrick skin phototyping scale and reflectance spectrophotometry. Differences in emissivity values between skin pigmentation groups were assessed by one-way ANOVA. RESULTS: The mean calculated emissivity for the 65 participants was 0.972 (range 0.96-0.99). No significant differences in emissivity were observed between participants when grouped by skin pigmentation according to the Fitzpatrick scale (p = 0.859) or reflectance spectrophotometry (p = 0.346). CONCLUSION: These data suggest that skin pigmentation does not affect thermal emissivity measurement of skin temperature using thermal infrared imaging. This study will aid further research into the application of thermal infrared imaging as a screening or bedside diagnostic tool in clinical practice.


Subject(s)
Infrared Rays , Skin Pigmentation , Skin Temperature , Thermography/methods , Adult , Aged , COVID-19/diagnosis , COVID-19/virology , Ethnicity , Female , Healthy Volunteers , Humans , Male , Middle Aged , Prospective Studies , SARS-CoV-2 , Spectrophotometry/methods , Young Adult
17.
BMJ Open ; 10(7): e038555, 2020 07 22.
Article in English | MEDLINE | ID: covidwho-662505

ABSTRACT

INTRODUCTION: There is an outbreak of COVID-19 worldwide. As there is no effective therapy or vaccine yet, rigorous implementation of traditional public health measures such as isolation and quarantine remains the most effective tool to control the outbreak. When an asymptomatic individual with COVID-19 exposure is being quarantined, it is necessary to perform temperature and symptom surveillance. As such surveillance is intermittent in nature and highly dependent on self-discipline, it has limited effectiveness. Advances in biosensor technologies made it possible to continuously monitor physiological parameters using wearable biosensors with a variety of form factors. OBJECTIVE: To explore the potential of using wearable biosensors to continuously monitor multidimensional physiological parameters for early detection of COVID-19 clinical progression. METHOD: This randomised controlled open-labelled trial will involve 200-1000 asymptomatic subjects with close COVID-19 contact under mandatory quarantine at designated facilities in Hong Kong. Subjects will be randomised to receive a remote monitoring strategy (intervention group) or standard strategy (control group) in a 1:1 ratio during the 14 day-quarantine period. In addition to fever and symptom surveillance in the control group, subjects in the intervention group will wear wearable biosensors on their arms to continuously monitor skin temperature, respiratory rate, blood pressure, pulse rate, blood oxygen saturation and daily activities. These physiological parameters will be transferred in real time to a smartphone application called Biovitals Sentinel. These data will then be processed using a cloud-based multivariate physiology analytics engine called Biovitals to detect subtle physiological changes. The results will be displayed on a web-based dashboard for clinicians' review. The primary outcome is the time to diagnosis of COVID-19. ETHICS AND DISSEMINATION: Ethical approval has been obtained from institutional review boards at the study sites. Results will be published in peer-reviewed journals.


Subject(s)
Artificial Intelligence , Coronavirus Infections/diagnosis , Mobile Applications , Pneumonia, Viral/diagnosis , Quarantine , Smartphone , Wearable Electronic Devices , Betacoronavirus , Blood Gas Monitoring, Transcutaneous , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Cloud Computing , Coronavirus Infections/physiopathology , Early Diagnosis , Heart Rate , Hong Kong , Humans , Pandemics , Pneumonia, Viral/physiopathology , Respiratory Rate , SARS-CoV-2 , Skin Temperature , Telemedicine
18.
Int J Environ Res Public Health ; 17(13)2020 Jun 27.
Article in English | MEDLINE | ID: covidwho-624585

ABSTRACT

Individual respiratory protective devices and face masks represent critical tools in protecting health care workers in hospitals and clinics, and play a central role in decreasing the spread of the high-risk pandemic infection of 2019, coronavirus disease (COVID-19). The aim of the present study was to compare the facial skin temperature and the heat flow when wearing medical surgical masks to the same factors when wearing N95 respirators. A total of 20 subjects were recruited and during the evaluation, each subject was invited to wear a surgical mask or respirator for 1 h. The next day in the morning at the same hour, the same subject wore a N95 mask for 1 h with the same protocol. Infrared thermal evaluation was performed to measure the facial temperature of the perioral region and the perception ratings related to the humidity, heat, breathing difficulty, and discomfort were recorded. A significant difference in heat flow and perioral region temperature was recorded between the surgical mask and the N95 respirator (p < 0.05). A statistically significant difference in humidity, heat, breathing difficulty, and discomfort was present between the groups. The study results suggest that N95 respirators are able to induce an increased facial skin temperature, greater discomfort and lower wearing adherence when compared to the medical surgical masks.


Subject(s)
Coronavirus Infections/prevention & control , Hand , Masks , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Respiratory Protective Devices , Skin Temperature , Betacoronavirus , COVID-19 , Health Personnel , Hot Temperature , Humans , Humidity , Infrared Rays , Male , Middle Aged , Respiration , SARS-CoV-2 , Thermography
SELECTION OF CITATIONS
SEARCH DETAIL